4.3 Aseptic Technique

In addition to using standard precautions and transmission-based precautions, aseptic technique (also called medical asepsis) is the purposeful reduction of pathogens to prevent the transfer of microorganisms from one person or object to another during a medical procedure. For example, a nurse administering parenteral medication or performing urinary catheterization uses aseptic technique. When performed properly, aseptic technique prevents contamination and transfer of pathogens to the patient from caregiver hands, surfaces, and equipment during routine care or procedures. The word “aseptic” literally means an absence of disease-causing microbes and pathogens. In the clinical setting, aseptic technique refers to the purposeful prevention of microbe contamination from one person or object to another. These potentially infectious, microscopic organisms can be present in the environment, on an instrument, in liquids, on skin surfaces, or within a wound.

There is often misunderstanding between the terms aseptic technique and sterile technique in the health care setting. Both asepsis and sterility are closely related, and the shared concept between the two terms is removal of harmful microorganisms that can cause infection. In the most simplistic terms, asepsis is creating a protective barrier from pathogens, whereas sterile technique is a purposeful attack on microorganisms. Sterile technique (also called surgical asepsis) seeks to eliminate every potential microorganism in and around a sterile field while also maintaining objects as free from microorganisms as possible. It is the standard of care for surgical procedures, invasive wound management, and central line care. Sterile technique requires a combination of meticulous hand washing, creation of a sterile field, using long-lasting antimicrobial cleansing agents such as betadine, donning sterile gloves, and using sterile devices and instruments.

Principles of Aseptic Non-Touch Technique

Aseptic non-touch technique (ANTT) is the most commonly used aseptic technique framework in the health care setting and is considered a global standard. There are two types of ANTT: surgical-ANTT (sterile technique) and standard-ANTT.

Aseptic non-touch technique starts with a few concepts that must be understood before it can be applied. For all invasive procedures, the “ANTT-approach” identifies key parts and key sites throughout the preparation and implementation of the procedure. A key part is any sterile part of equipment used during an aseptic procedure, such as needle hubs, syringe tips, needles, and dressings. A key site is any nonintact skin, potential insertion site, or access site used for medical devices connected to the patients. Examples of key sites include open wounds and insertion sites for intravenous (IV) devices and urinary catheters.

ANTT includes four underlying principles to keep in mind while performing invasive procedures:

  • Always wash hands effectively.
  • Never contaminate key parts.
  • Touch non-key parts with confidence.
  • Take appropriate infective precautions.

Preparing and Preventing Infections Using Aseptic Technique

When planning for any procedure, careful thought and preparation of many infection control factors must be considered beforehand. While keeping standard precautions in mind, identify anticipated key sites and key parts to the procedure. Consider the degree to which the environment must be managed to reduce the risk of infection, including the expected degree of contamination and hazardous exposure to the clinician. Finally, review the expected equipment needed to perform the procedure and the level of key part or key site handling. See Table 4.3 for an outline of infection control measures when performing a procedure.

Table 4.3 Infection Control Measures When Performing Procedures

Infection Control Measure Key Considerations Examples
Environmental control
  • Recognize and avoid risks in the environment that may increase risk of infection.
  • Ensure clean bed linens.
  • Monitor patient lines that are near or across work areas.
  • Clean surfaces before establishing a work area.
  • Keep food and personal items away from working areas.
Hand hygiene
  • Perform hand hygiene frequently and during key moments. (Review the Five Key Moments under the “Appropriate Hand Hygiene” section.)
  • Scrub with soap solution and water for 20-30 seconds.
  • Use alcohol-based rub until dry, unless hands are visibly soiled or the patient has C-diff.
Personal protective equipment (PPE)
  • Select sterile or clean gloves based on the need to touch key parts or key sites directly.
  • Gloves do not replace the need for hand hygiene.
  • Gloves (sterile or clean, based on the procedure)
  • Mask or respirator
  • Protective eyewear, goggles, or face shield
  • Gown (sterile or clean, whichever is appropriate)
Aseptic field management Determine level of aseptic field needed and how it will be managed before the procedure begins:

  • General aseptic field: Key parts and sites are easily protected. Sterile field does not need to be set up and managed as a key part.
  • Critical aseptic field: Key parts and sites are large, numerous, or not easily protected using non-touch technique. Sterile field needs to be established before and managed during procedure.
General aseptic field:

IV irrigation

Dry dressing changes

Critical aseptic field:

Urinary catheter placement

Central line dressing change

Sterile dressing change

Non-touch technique
  • Non-touch is the primary goal, even when sterile gloves are used.
  • Requires preparation and knowledge of planned procedure sequencing.
  • Touching key sites and key parts is limited, purposeful, and only when needed.
  • Handling key parts only at the time needed to assemble or use in procedure
  • Handling syringes away from the hub
  • Applying bandages by the edges away from key parts that will contact key sites
Sequencing
  • Order of procedure requires planning to be efficient, logical, and safe.
  • Practicing guidelines give direction as to optimal order from preparation to completion.
  • Generally, follow “clean to dirty” standards, working from least to most contaminated key parts and sites.

Use of Gloves and Sterile Gloves

There are two different levels of medical-grade gloves available to health care providers: clean (exam) gloves and sterile (surgical) gloves. Generally speaking, clean gloves are used whenever there is a risk of contact with body fluids or contaminated surfaces or objects. Examples include starting an intravenous access device or emptying a urinary catheter collection bag. Alternatively, sterile gloves meet FDA requirements for sterilization and are used for invasive procedures or when contact with a sterile site, tissue, or body cavity is anticipated. Sterile gloves are used in these instances to prevent transient flora and reduce resident flora contamination during a procedure, thus preventing the introduction of pathogens. For example, sterile gloves are required when performing central line dressing changes, insertion of urinary catheters, and during invasive surgical procedures. See Figure 4.15[1] for images of a nurse opening and removing sterile gloves from packaging.

See the “Checklist for Applying and Removing Sterile Gloves” for details on how to apply sterile gloves.

Applying Sterile Gloves on YouTube[2]

 

Photos showing opening of sterile gloves package
Figure 4.15 Sterile Gloves

  1. “Book-pictures-2015-199-001-300x241.jpg,” “Book-pictures-2015-215.jpg,” and “Book-pictures-2015-219.jpg” by British Columbia Institute of Technology are licensed under CC BY 4.0. Access for free at https://opentextbc.ca/clinicalskills/chapter/sterile-gloving/
  2. RegisteredNurseRN. (2017, April 28). Sterile gloving nursing technique | Don/donning sterile gloves tips. [Video]. YouTube. All rights reserved. Video used with permission. https://youtu.be/lumZOF-METc
definition

License

Icon for the Creative Commons Attribution 4.0 International License

Nursing Skills - 2e Copyright © 2023 by Chippewa Valley Technical College is licensed under a Creative Commons Attribution 4.0 International License, except where otherwise noted.